Performance Water Filters

Patti Wilson Authorized Multi-Pure Independent Distributor #414220 Saint Augustine, Florida Phone 904 940 4977 Email: patti@supremedrinkingwatersolutions.com
Home Page
MultiPure Special Offers
MultiPure Reverse Osmosis
Reverse Osmosis
Under Sink Systems
Counter Top Systems
Whole House Filters
Inline Filters
FilterMania
Model MP880EL
MultiPure MP880SB
MultiPure MP880SC
MultiPure MP880SI Water F
MultiPure MP1200EL Water
MultiPure Model MP750SB
MultiPure MP750SC
MultiPure MPCT
Inline Water Filters
MultiPure MPAD
Multi-Pure Faucets
MultiPure H2O Bottles
Multi Pure Shower Filters
MultiPure Crystal Bath
NSF Certification
MultiPure MP880 NSF Certi
Replacement Water Filters
Emergency Kit
Water News
Tap Water Report
How It Works
MultiPure Business Opport
Facts About Arsenic
FRIENDLY LINKS
How To Compare
Arsenic In Drinking Water
Site Map
EWG Tap Water Study
About Us
Contact Us
Multi-Pure Triple Guarant
Multi Pure Water Filters Are Tried, Tested, Proven, and NSF Certified
Since 1970, Multi-Pure has been a leader in the water filtration industry producing solid carbon block drinking water filtration products.  Multi-Pure Solid Carbon Block technology reduces a much wider range of contaminants of health concern than other water filters on the market today.  If you are looking for a water filter that produces healthier, better tasting drinking water, MultiPure is without a doubt, Your best choice in a water filter. 
 
 
NSF International set the standards and provides 3rd party testing of water filtration products...  NSF tests the quality and performance of water filters.  NSF also monitors the manufacturing process.  MultiPure Water Filters are tested, proven, and certified by NSF....
 
Multi Pure Solid Carbon Block Water Filters are tested according to NSF/ANSI Standard 53 - Health Effects for the reduction of:
 
                      Alachlor     98%                                              
                      Asbestos   99.9%
                      Atrazine     97%
                      Benzene    99%
                      Bromodichloromethane   99.8%
                      Bromoform    99.8%
                      Carbofuran     99%
                      Carbon Tetrachloride    98%
                      Chlordane     99.5%
                      Chlorobenzene    99%
                      Chloropicrin    99%
                      Chloroform      99.8%
                      Cryptosporidium Cysts    99.95%
                      Giardia Cysts    99.95%
                      Entamoeba       99.95%
                      Toxoplasma      99.95%
                      2, 4-D               98%
                      DBCP               99%
                      1,2-DCA            95%
                      1,1-DCE            99%
                      Dibromochloromethane
                         (TTHM: Chlorodibromomethane) 99.8%
                      Dibromochloropropane (DBCP)   99%
                      o-Dichlorobenzene
                         (1,2 Dichlorobenzene)  99%
                      p-Dichlorobenzene
                         (para-Dichlorobenzene) 98%
                      1,2-Dichloroethane (1,2-DCA)  95%
                      1,1-Dichloroethylene  (1,1-DCE)  99%
                      Cis-1,2-Dichloroethylene   99%
                      Trans-1,2-Dichloroethylene  99%
                      1,2-Dichloropropane
                         (Propylene Dichloride)   99%
                      CIS-1,3-Dichloropropylene   99%
                      Dinoseb    99%
                      EDB (see Ethylene Dibromide)   99%
                      Endrin   99%
                      Ethylbenzene    99%
                      Ethylene Dibromide (EDB)   99%
                      Furadan (see Carbofuran)    99%
                      Haloacetonitriles (HAN)   
                              Bromochloroacetonitrile  98%
                              Dibromoacetonitrile     98%
                              Dichloroacetonitrile     98%
                              Trichloroacetonitrile     98% 
                      Haloketones (HK)
                              1,1-Dichloro-2-Propanone   99%
                              1,1,1-Trichloro-2-Propanone   96%
                     Heptachlor   99%
                     Heptachlor epoxide  98%
                     Hexachlorobutadiene  99%
                     Lead (ph 6.5)     99.3%
                     Lead (ph 8.5)     99.3%
                     Lindane   99%
                     Mercury (ph 6.5)     99%
                     Mercury (ph 8.5)     99%
                     Methoxychlor     99%
                     Methylbenzene (see Toluene)     99%
                     Monochlorobenzene (see Chlorobenzene)    99%
                     MTBE (methyl tert-butyl ether)     96.6%
                     Polychlorinated Biphenyls (PCB's, Aroclor 1260)   99.9%
                     PCE (see Tetrachloroethylene)    99%
                     Pentachlorophenol     99%
                     Perchlorobutadiene  (see Hexachlorobutadiene)   98%
                     Propylene Dichloride (see 1,2-Dichloropropane)  99%
                     Simazine    97%
                     Silvex (see 2,4,5-TP)   99%
                     Styrene (Vinylbenzene)     99%
                     1,1,1-TCA (see 1,1,1 - Trichloroethane)   95%
                     TCE  (see Trichloroethylene)    99%
                     1,1,2,2- Tetrachloroethane    99%
                     Tetrachloroethylene    99%
                     Toluene (Methylbenzene)   99%
                     Toxaphene       92.9%
                     Toxoplasma     99.95%
                     2,4,5-TP (Silvex)   99%
                     Tribromoacetic Acid
                         1,2,4 Trichlorobenzene (Unsymtrichlorobenzene)    99%
                         1,1,1 - Trichloroethane (1,1,1-TCA)   95%
                         1,1,2-Trichloroethane   99%
                     Trichloroethylene (TCE)   99%
                     Trihalomethanes (TTHM) (Chloroform; Bromoform;
                           Bropmodichloromethane; Dibromochloromethane)    99.8%
                     Turbidity     99%
                     Unsym-Trichlorobenzene  (see 1,2,4,-Trichlorobenzene)   99%
                     Vinylbenzene (see Styrene)     99% 
                     Xylenes (Total)   99%
 
 
NSF/ANSI 42- Aesthetic Effects  
                                                   
                     Chloramine as Aesthetic Effect (as Monochloramine)    97%
                     Chlorine as Aesthetic Effect   99%
                     Particulate, (Nominal Particulate Reduction, Class 1, Particles 0.5 to<1 UM)   Class 1  =   99%
 
Multi-Pure's MP880 Series has benn tested according to NSF/ANSI Standard 53 for the reduction of the following
substances.  (This is in addition to all the above contaminants under Standard 53 and 42 )
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system.
 
                      Arsenic (pentavalent As (V); As (+5); arsenate@ 6.5 ph     99.9%
                      Arsenic (pentavalent As (V); As (+5); arsenate@ 8.5ph      95.8%
 
 
NSF/ANSI Standard 58 - Reverse Osmosis
 
MultiPure's MP750PlusRO has been tested according to NSF/ANSI Standard 58 for the reduction of the following substances.  The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
 
                        Arsenic V (pentavalent AS (V); As (+5); arsenate)    98.4%
                        Barium     97.9%
                        Cadmium 98.6%
                        Chromium, Hexavalent  91.3%
                        Chromium, Trivalent    94.1%
                        Copper    99.0%
                        Cysts (Giardia;  Cryptosporidium:  Entamoeba:  Toxoplasma)  99.99%
                        Fluoride  93.9%
                        Lead     98.6%
                        Nitrate    76.54%
                        Nitrite     82.14%
                        Nitrate/Nitrite   82.14%
                        Perchlorate    96.5%
                        Radium 226/228    80.0%
                        Selenium   92.0%
                        Total Dissolved Solids (TDS)   96.8%
 
  • Multi Pure Drinking Water Filters have been certified, as indicated, by NSF International for compliance to  NSF/ANSI Standard Nos.42 and 53, and 58.
  • Multi-Pure Drinking Water Systems have been certified by the State of California Department of Health Services for the reduction of specific contaminants listed herein.
  • Chloroform was used as a surrogate for claims of reduction of Volatile Organic Chemicals (VOC's)  MultiPure Systems tested at >99.8% actual reduction of Chloroform.  Percent reduction shown herein reflects the allowable claims for VOCs as per tables in the Standard.
  • Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit.  Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. 
  • Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed.  For optimum performance, it is essential that the filter be replaced on a regularly scheduled basis as follows: (a) annually; (b) when the unit's rated capacity has been reached; (c) the flow rate diminishes; (d) the filter becomes saturated with bad tastes and/or odors...
  • Model Nos. MP1200EL and MP880EL include a capacity monitor that automatically flashes a yellow light when it is time to replace the filter.
  • Model no. MP750Plus Reverse Osmosis may be used with municipal or well water sources that are treated and tested on a regular basis to ensure bacteriological safe quality of the water.
  • Do not allow water to freeze in the unit.  If unit is exposed to freezing temperatures, drain water from unit and remove filters.
  • Do not allow water to sit in unit for extended periods of time (10 or more days) without being used.  If unit is to be left unused for more than 10 days, drain all water from the system and remove the filters.  Upon your return, reconnect the filters in the housing and continue use.  In the event water does sit in the unit for 10 or more days, the system should be flushed by allowing water to flow to waste for about 10 minutes;  then continue use as normal.
  • Multi-Pure Drinking Water Systems stainless steel units is warranted for a period of 25 years; plastic unit is warranted for 5 years.  All exterior hoses and attachments to the system are warranted for defects in material and workmanship for one year.  Please see the Owner's Manual for complete product guarantee and warranty information.
  • Please see the Owner's Manual for installation instructions and operating procedures.
  • In compliance with New York law, it is recommended that before purchasing a water treatment system, NY residents have their water supply tested to determine their actual water treatment needs.  Please compare the capabilities of the Multi-Pure Water Filter Unit with your actual water treatment needs.
  • Check for compliance with state and local laws and regulations.
  • While testing was performed under standard laboratory conditions, actual performance may vary.
  • The list of substances which the treatment device reduces does not necessarily mean that these substances are present in our tap water.
  • MultiPure Model No. MP750Plus Reverse Osmosis  is acceptable for treatment of influent concentrations of no more than 27mg/L nitrate and 3mg/l nitrite in combination measured as N and is certifed for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
  • Multi Pure's MP880 Series and MP750Plus Reverse Osmosis have been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5), or arsenate) at concentrations of 0.30 mg/L or less.  This system, MultiPure MP750Plus Reverse Osmosis reduces pentavalent arsenic, but may not remove other forms of arsenic.  This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic.  Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic.  Please see the Arsenic Facts section for further information.